Pressure gauge


A simple way of checking the pressure gauge is to mount a completely new set of nozzles, which are known to match the values of the nozzle table.

At a fixed working pressure – e.g. 3 bar – the nozzle flow rate is calibrated with a measuring jug.

If the flow rate of the nozzles matches the table value at this pressure, the pressure gauge is OK.